Sync external data
Sync data from a connected external system to a Ninox table.
Use a connector to sync data from an external source into a new or existing Ninox table.
Create a new synced table
Create a new Ninox table from data in an external system.
Open live data connections
Open the app and click the arrow next to Create table.
Alternatively, click More in the top bar.

Under Connect live data, select the connector you want to use. Select More connections to choose another connector.
Review the connector's available capabilities. Click Connect to set up the connection.
Set up the connection
Enter a Connection name. Under Who logs in, choose the account scope:
Organization account: Shares one account across the organization. Select the workspaces where the connection is available.
Workspace account: Shares one account with everyone in the current workspace.
Personal account: Each workspace user connects their own external-system account.
Enter the required credentials for the connector, such as an API key. Click Connect to finish.
Configure sync settings
Configure the header cell, record matching, sync interval, and sync direction.
See Configure sync settings for a new table for details.
Configure sync settings
Configure the header cell, record matching, sync interval, and sync direction.
See Configure sync settings for a new table for details.
Configure sync settings for a new table
Use Sync settings to configure the target table, source, and synchronization behavior.
In Target table, select Create table.
Then configure the following settings:
Connection: Select the connector that provides the source data.
Source: Select an available source. Another Source selector may appear to refine your selection. For example, select a sheet, then a tab. The available options and number of Source selectors depend on the connection and your setup.
Header cell: For Google Sheets and Microsoft Excel, enter the cell that contains the source column headings, such as
A1.Match records by: For Google Sheets and Microsoft Excel, select Row position to match records by their position in the source.
Sync interval: Select Manual, Every 15 minutes, Hourly, or Daily. The available options depend on your plan.
Sync direction: Select One way (Read-only) to import source data into Ninox. Select Both ways (Read and write) to synchronize changes in both systems.
Name: Enter a name and select an icon for the table.
Sync external data with an existing table
Sync external data with a table that already exists in your app.
Open live data connections
Open the app and click the arrow next to Create table.
Alternatively, click More in the top bar.
Under Connect live data, select the connector you want to use. Select More connections to choose another connector.
Review the connector's available capabilities. Click Connect to set up the connection.
Set up the connection
Enter a Connection name. Under Who logs in, select Organization account to share one account across the organization or Workspace account to use one shared account in the current workspace.
Enter the required credentials for the connector, such as an API key. Click Connect to finish.
Configure sync settings
Configure the record matching, sync interval, sync direction, and initial import.
See Configure sync settings for an existing table for details.
Map source fields
Open Map fields and map source columns to Ninox fields.
See Map source fields for details.
Configure sync settings
Configure the record matching, sync interval, sync direction, and initial import.
See Configure sync settings for an existing table for details.
Map source fields
Open Map fields and map source columns to Ninox fields.
See Map source fields for details.
Configure sync settings for an existing table
Use Sync settings to configure the target table, source, and synchronization behavior.
In Target table, select the Ninox table that you want to sync.
Then configure the following settings:
Connection: Select the connector that provides the source data.
Source: Select the source file, then the sheet, tab, or dataset to sync. The available options depend on the selected external system.
Header cell: For Google Sheets and Microsoft Excel, enter the cell that contains the source column headings, such as
A1.Match records by: For Google Sheets and Microsoft Excel select:
Key column to match records by a unique value. Select the key column in the selector that appears below. Ninox updates only records with matching key values.
Row position to match records by their position in the source. During synchronization, Ninox overwrites the existing data with values from the matching source row.
Sync interval: Select Manual, Every 15 minutes, Hourly, or Daily. The available options depend on your plan.
Sync direction: Select One way (Read-only) to import source data into Ninox. Select Both ways (Read and write) to synchronize changes in both systems.
Initial import: Select Update and add records to update matching records and add new ones. Select Add new records only to import only source records that do not already exist. This option is unavailable when you match records by Key column.
Map source fields
Open Map fields to define how source data is imported into the target table. For each source column, choose whether to import it, then map it to an existing Ninox field or create a new field. This ensures that source values are stored in the correct field.
For each source column, you can:
turn Import on or off
select an existing Ninox field or select Create field
Sync a table after setup
After you create a synced table, its top bar shows the latest synchronization status, such as Synced 10 secs ago. The color indicates how many records changed during that synchronization:
Green: No records changed.
Orange: 1 to 50 records changed.
Red: More than 50 records changed.
Click the icon at any time to synchronize the table manually.
When you select a fixed sync interval during configuration, such as Every 15 minutes, Hourly, or Daily, Ninox synchronizes the table automatically at that interval.
When Sync interval is set to Manual, click Sync in the top bar to update the table.
If the external system requires authentication, Ninox shows Log in to sync instead of Sync. Click it and sign in before the next synchronization. For tables that use each user's external-system account, connect your account under Connections in the workspace settings. To connect it, click the icon in the connectors list.
Change settings for an existing synchronization
Change the Sync interval and Sync direction, or Edit field mapping at any time.
In the settings panel, select the Table tab, then select the Settings tab.
Under Sync, you find:
Sync interval
Sync direction
Edit field mapping
Stop the synchronization
If you no longer need to sync a table, stop the synchronization in the table settings.
In the settings panel, select the Table tab, then select the Settings tab.
Under Sync, click Stop syncing.

Last updated
Was this helpful?